Log file of the Pro/ENGINEER to think3 conversion

When you open a Pro/ENGINEER file, a log file of the conversion is created:

The log file structure

The Pro/ENGINEER to think3 conversion log file has a structure made of the following sections:

Warnings and errors help you identify any kind of problem you might have had while converting a Pro/ENGINEER file.
You can find details about the errors that occurred, if any, in the error log file.

Example of Pro/ENGINEER to think3 conversion log file

Here is an example of a log file:

Pro/ENGINEER (TM) file reader.
Reading data from file  : E:\Vault\ProE\arm.prt


__________ Parsing phase   ________________________________________


 PRO-E:PRT PART

 VERSION : Pro Engineer 2000i2


__________ Reader options  ________________________________________

General read options
Reading Mode            : Brep
Read Construction/Datum : No
Read Texts/3dNotes      : No
Display visible datum : Yes

Assembly read options
Load References         : Yes

Search directories
Directory               : E:\Vault\ProE
Recursive search        : Yes


__________ Information     ________________________________________

Model name              : arm
Version/Release         : Pro Engineer 2000i2
Unit (multiple of mm)   : 25.4

Model Dimension         : 49.739359
Bounding Box Min        : Xmin=-6.811243, Ymin=-6.370243, Zmin=-2.245243
Bounding Box Max        : Xmax=8.245243, Ymax=2.249411, Zmax=44.370286
Accuracy                : 0.001200

__________ Reading phase   ________________________________________


__________ Summary         ________________________________________


Details:

   OUT OF FILTER      SUCCESS          FAIL        NOT TREATED    TYPE
         0               1               0               0        PART
         0             118               0               0        FACE
  ---------------------------------------------------------------------
         0             119               0               0        TOTAL

Standard:

          TO BE PROCESSED        |   FAIL  |         CREATED                
  --------------------------------------------------------------------------
  |      1 Solid [118]           |    0    |       1 Solid [118]           |
  --------------------------------------------------------------------------
         1                       |    0    |       1 TOTAL                  

Number of errors : 0
Number of warnings : 0


-------------------- Conversion Report --------------------

Converted file: E:\Vault\ProE\\arm.prt


Type Name Count
----------------------------------------

-1 Solid 1
3 CPntCv3d 244
6 CPntSrf 55
20 Line3d 39
36 PlaneSrf 22
46 CylSrf 41


Total Number of Entities Converted: 402

--------------------------------------------------------------------------